Temperature Sensing Devices for Electric Motors: Selection, Application & SA Availability
Discover how to choose, apply, and source temperature sensing devices for electric motors: RTDs, thermistors, and thermocouples compared for SA industry.

Device Options Explained
Compare RTDs, thermistors, and thermocouples for motor temperature monitoring.
Selection & Application Guide
Learn which sensor best suits your motor type, duty cycle, and installation constraints.
Stocked Locally by Communica
Find popular brands and device types in stock for fast SA delivery or local pickup.
Overview: Why Monitor Motor Temperature?
Temperature sensing in electric motors is critical for preventing thermal overload, improving efficiency, and extending operational life. Motors exposed to high ambient conditions, heavy-duty cycles, or enclosed spaces are especially at risk for overheating. Proactive temperature monitoring is increasingly standard in South African industry - from mines and processing plants to HVAC systems, manufacturing, and pump stations.
This guide details the main classes of temperature sensors used with electric motors, their working principles, where they are applied, and how to select the right solution for your requirements. Guidance is provided for engineers, technicians, and plant procurement teams working with commonly stocked motors and available sensor brands at Communica.
Types of Temperature Sensing Devices for Motors
| Sensor Type | Typical Range | Output Signal | Response | Example Brands |
|---|---|---|---|---|
| RTD (Pt100/Pt1000) | -50 degreesC to +250 degreesC | Resistance (Ohm) | High accuracy, slower | Omega, TE Connectivity, Honeywell |
| Thermistor (NTC/PTC) | -40 degreesC to +150 degreesC | Resistance (Ohm) | Fast response | EPCOS, Amphenol, Murata |
| Thermocouple (Type K/T/J) | -200 degreesC to +1200 degreesC | Voltage (mV) | Wide range, rugged | Omega, ABB, Adafruit |
| Embedded Thermal Switch | Preset trip | On/Off (binary) | Instantaneous | Kemo, Honeywell |
Where Are Sensors Installed?
- Embedded in stator windings (high-voltage motors)
- Fixed to motor frame/surface (universal retrofit)
- Inside terminal boxes (for thermal probes/switches)
- Via clamp-on probes for temporary diagnostics
Choice of device and installation depends on motor construction, repair access, and monitoring precision required.
Key Specifications & Standards
- Temperature range and tolerance/class (e.g., Class A/B for RTD)
- Probe shape/form factor (bead, probe, ring lug, embedded array)
- Ingress Protection (IP) for surface-mount and exposed devices
- Electrical connection (flying lead, terminal, PCB pin)
- Resistance/voltage characteristics-compatible with your motor control/PLC
Related Sensors & Semiconductors Products
Discover quality sensors & semiconductors products related to Temperature Sensing Devices for Electric Motors: Selection, Application & SA Availability
Ema Ta1004 Programmable Temp Sensor Stainless Steel -40 - +150 Deg. C 4-20ma Output 1 Npn/pnp Output 2 - M18 X 1,5 External Thread Ip68
Ema Ta1004 Programmable Temp Sensor Stainless Steel -40 - +150 Deg. C 4-20ma Output 1 Npn/pnp Output 2 - M18 X 1,5 External Thread Ip68
Selection Criteria for Motor Temperature Sensors
- Required accuracy: For critical control or alarms, PT100 RTDs are the standard; for simple over-temp shutdown, PTC thermistors or thermal switches suffice.
- Response time: Thermistors and thermocouples respond fastest to winding/external changes.
- Environmental robustness: If the sensor faces vibration or dust, encapsulated or IP-rated units last longer.
- Integration: Confirm compatibility of outputs with your protection relay, soft starter, or PLC. Most modern motor protection relays accept 3-wire Pt100 or standard PTC inputs.
- Physical fit: Select correct probe or element dimension for winding or bore size, or choose adhesive/clamp surface sensors for retrofits.
Basic Calculations & Example Readings
For an industrial 7.5kW induction motor, designers often specify 3x Pt100 sensors in stator windings. With a standard Pt100 (alpha=0.00385), resistance at 0 degreesC (R0) is 100Ohm. Resistance at a given temperature (T degreesC) is calculated:
RT = R0 x (1 + alpha x T)
At 120 degreesC winding temp:
R120 = 100 x (1 + 0.00385 x 120) ~ 146.2Ohm
The protection relay trips at R = 146Ohm, safeguarding windings from thermal failure. SA users often pair local ABB or Siemens relays with PT100-protected motors.
Troubleshooting & Maintenance Tips
- Monitor for drifting resistance or open-circuit faults (especially after winding replacement).
- For thermocouple systems, check that extension leads match the sensor type (Type K lead for K sensor).
- Clean surface sensors periodically to avoid thermal lag from dust buildup.
- Test alarm and shutdown circuits during routine maintenance; verify actual trip temperatures with a handheld thermometer.
Locally Popular Brands & Sourcing via Communica
Communica stocks RTDs, thermistors, thermocouples, and accessories from trusted brands like Omega, EPCOS (TDK), ABB, Amphenol, and Honeywell. Popular ranges include embedded windings sensors, ring-lug and probe thermistors, and pre-wired thermal switches. Spares and extension cables are usually available for branch collection or delivery nationwide.
Start your search in the Sensors and All Products categories, or browse by brand to match relay and sensor elements for your site.
Sources
Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.
Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.
Frequently Asked Questions
Get answers to common questions about Sensors And Semiconductors
Why Choose Communica?
*Free Shipping
Free shipping for orders over ZAR 1,000.00.
7-Day Returns
Get a full refund if you had the product for less than 7 days.
Quick Delivery
Nationwide delivery within 2 - 4 working days.


