Comparison of CAB01PR22MSCR with Other Network Cables - Features & Use Cases (South Africa)
Compare CAB01PR22MSCR with Cat5e, Cat6 and Cat6A cables. Learn about bandwidth, shielding, conductor type, installation tips and South Africa procurement notes.

Know the Category
Identify whether CAB01PR22MSCR meets Cat6 or Cat6A for your speed needs.
Choose Conductor Type
Use stranded for patch leads, solid for permanent in-wall runs.
Local Procurement Tips
Request datasheets, channel tests and check branch pickup times.
Overview: What CAB01PR22MSCR Is and Why Compare
The keyword CAB01PR22MSCR typically refers to a specific SKU or product code for a pre-terminated network cable assembly. This guide compares that part against common network cable types (Cat5e, Cat6, Cat6A) and assembly styles used by South African makers, students, technicians and procurement teams. We focus on electrical and mechanical specs, installation factors, performance in local conditions, and selection advice for office, lab or factory networks.
Quick technical snapshot
When comparing any specific SKU to generic cable categories, key attributes are conductor size (AWG), pair twisting, shielding (UTP, FTP, STP), impedance (100 Ohm), max frequency (MHz), and whether the cable is stranded or solid. Pre-terminated assemblies add connector quality, strain relief, jacket material and tested channel performance.
Common comparison points
- Rated category (Cat5e / Cat6 / Cat6A)
- Shielding: UTP vs FTP vs S/FTP
- Conductor: solid vs stranded and AWG size
- Bandwidth / frequency rating (MHz) and supported PHYs (100BASE-T, 1G, 10G)
- Environmental and jacket rating (PVC, LSZH) and temperature range
- Termination quality and channel test results (where available)
Specification comparison table
| Attribute | CAB01PR22MSCR (typical SKU) | Cat5e (standard) | Cat6 | Cat6A |
|---|---|---|---|---|
| Typical bandwidth | Depends on assembly; often 250 MHz (Cat6) or 500 MHz (Cat6A) | 100 MHz | 250 MHz | 500 MHz |
| Max data rate | 1 Gbit/s typical; 10 Gbit/s possible if Cat6A spec | 1 Gbit/s (100m) | 1 Gbit/s (100m); 10 Gbit/s limited to shorter runs | 10 Gbit/s (up to 100m) |
| Conductor | Often 24 AWG stranded for patch leads; solid for in-wall runs | 24 AWG solid | 23-24 AWG solid | 23 AWG solid |
| Shielding | Varies: UTP or screened (FTP/S/FTP) options | Usually UTP | UTP or screened | Often shielded to reduce alien crosstalk |
| Jacket materials | PVC or LSZH options available | PVC/LSZH | PVC/LSZH | PVC/LSZH |
Note: the exact CAB01PR22MSCR details depend on the manufacturer's datasheet. For procurement in South Africa, request the datasheet and channel test report (if needed) to confirm category and performance.
Practical tip: For patch leads and bench use, stranded 24 AWG pre-terminated assemblies (like many SKU-style cables) are more flexible. For permanent in-wall runs, choose solid conductor cables matched to the outlet and patch panels.
Related Connectors, Wire & Cable Products
Discover quality connectors, wire & cable products related to Comparison of CAB01PR22MSCR with Other Network Cables - Features & Use Cases (South Africa)
Hikvision Ds-1ln5e-e/e Cat5 Utp Solid Copper Network Cable
Hikvision Ds-1ln5e-e/e Cat5 Utp Solid Copper Network Cable
Hikvision Ds-1ln6u-g Network Cable Cat6 Utp Solid Copper
Hikvision Ds-1ln6u-g Network Cable Cat6 Utp Solid Copper
Hikvision Hkv Ds-1ln6-uu Network & Communication Cable
Hikvision Hkv Ds-1ln6-uu Network & Communication Cable
Hikvision Hkv Ds-1ln6utc0 Network & Communication Cable
Hikvision Hkv Ds-1ln6utc0 Network & Communication Cable
Utp Cat6e 4pr Solid Cable Blue Cca
Utp Cat6e 4pr Solid Cable Blue Cca
Cat6a 4 Pair S/ftp 22awg High Speed Data Cable 10gb/ps Ethercat, Etherline, Ethernet, Profinet, Green Pvc Jacket Flame Retardant - 100 Ohm
Cat6a 4 Pair S/ftp 22awg High Speed Data Cable 10gb/ps Ethercat, Etherline, Ethernet, Profinet, Green Pvc Jacket Flame Retardant - 100 Ohm
Helukabel Paar-tronic -li-2ycyv Pe-insulated Stranded Data Cable Black 2x2 0.22mm
Helukabel Paar-tronic -li-2ycyv Pe-insulated Stranded Data Cable Black 2x2 0.22mm
Cabcom08f | Comms Cable 8 Core Stranded • 0.45mm2 Each • White Colour (price Per Meter)
Cabcom08f | Comms Cable 8 Core Stranded • 0.45mm2 Each • White Colour (price Per Meter)
Cab08pr,50mscr | Mylar Screened 0.5mm 8pr Grey Pvc Cable (price Per Meter)
Cab08pr,50mscr | Mylar Screened 0.5mm 8pr Grey Pvc Cable (price Per Meter)
Opx It-utp5egy3-pvc | Cat5e Utp P/cord 3 Meter- Grey
Opx It-utp5egy3-pvc | Cat5e Utp P/cord 3 Meter- Grey
Mod Cable 8w Black | Modular Cable 8 Way Black
Mod Cable 8w Black | Modular Cable 8 Way Black
Mod Cable 4w Black | Modular Cable 4 Core Line Cord Black Modular Cable 4 Core Line Cord Black
Mod Cable 4w Black | Modular Cable 4 Core Line Cord Black Modular Cable 4 Core Line Cord Black
Selection Criteria & Calculations
Match cable selection to the application: 100BASE-T and 1G links are satisfied by Cat5e when runs are within spec, but for 10G or for future-proofing in office or lab environments, Cat6A or properly tested Cat6 channels are recommended. Consider these practical checks:
- Run length: longer runs increase attenuation; 100 m is the common horizontal limit.
- Environment: high EMI areas (near motors or heavy machinery) benefit from shielded cables.
- Flexing needs: use stranded patch leads for frequent movement; solid for permanent wiring.
- Connector quality and testing: pre-terminated assemblies should include channel test results (Fluke or equivalent) for guaranteed performance.
Attenuation & simple calculation example
Attenuation increases with frequency and length. Manufacturers publish dB/100m figures; as a rough example, a Cat6 cable might have 2.5 dB/100m at 100 MHz. For a 50 m run, expected attenuation ~ (2.5 dB/100m) x 0.5 = 1.25 dB. Lower is better; excessive attenuation can reduce signal-to-noise margin and impact higher-speed PHYs.
Wiring diagram (simple ASCII patch)
RJ45 plug (T568B) Network device [1] White-Orange ---------- TX+ [2] Orange ---------- TX- [3] White-Green ---------- RX+ [6] Green ---------- RX- (other pairs for PoE or 10G use)
Comparative use cases
- Home lab or student projects: Stranded pre-terminated patch leads (like CAB01PR22MSCR style) for flexibility and bench convenience.
- Small office (1G networks): Cat5e or Cat6 in-wall solid cores are cost-effective if future 10G isn't required.
- Enterprise or backbone runs (10G+): Cat6A shielded or unshielded with certified installation and testing.
- High-EMI factory floors: Use shielded pairs (FTP/S/FTP) and ensure proper grounding.
Local availability, brands and procurement notes (South Africa)
Communica stocks a wide range of cables and networking components suited to South African needs - including patch leads, bulk cable in PVC or LSZH jackets, and accessories like patch panels, keystone jacks and glands. Popular maker brands and general categories can be explored on Communica's product collections and networking categories. When ordering for education or institutional projects, request VAT invoices, lead-time estimates in working days, and confirm branch pickup options (Samrand, Pretoria CBD, Cape Town) to reduce delivery time.
Troubleshooting & installation tips
- Test each channel after installation with a network certifier for NEXT, return loss and wiremap to ensure category compliance.
- Avoid tight bends - maintain minimum bend radius (typically 4x cable diameter) to prevent pair untwisting and loss of performance.
- Label both ends of pre-terminated assemblies to simplify maintenance.
- For PoE applications, verify the cable and connector temperature rise at expected power levels; heavier gauge or better ventilation may be needed.
Decision checklist
- Confirm required data rate (1G vs 10G) and future-proofing needs.
- Choose stranded patch leads for flexibility; solid cores for permanent runs.
- Select shielding based on EMI and grounding capability in the installation area.
- Always request datasheet and test report for specific SKUs like CAB01PR22MSCR before bulk procurement.
Sources
- ISO/IEC standards overview for twisted-pair cabling
- Industry article: Introduction to Cat6A cabling
- Communica product collections and networking categories
- IEEE standards and physical-layer considerations
Estimated local procurement note: typical retail patch lead prices vary by length and spec; expect a wider price range for shielded Cat6A pre-terminated assemblies. Always confirm current stock and lead times on Communica's branches & trading hours page to plan collection or delivery.
Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.
Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.
Frequently Asked Questions
Get answers to common questions about Connectors Wire And Cable
Why Choose Communica?
*Free Shipping
Free shipping for orders over ZAR 1,000.00.
7-Day Returns
Get a full refund if you had the product for less than 7 days.
Quick Delivery
Nationwide delivery within 2 - 4 working days.
























