Troubleshooting Common Issues with Network and Communication Cables (South Africa)
Step-by-step troubleshooting for Ethernet, serial and field-bus cables. Learn tests, wiring diagrams, tools and South Africa buying tips for quick fixes and reliable links.

Start with the Patch Lead
Swap a known-good lead first to rule out the simplest fault.
Use Wiremap & Shielding
Verify pair order and shield grounding to reduce EMI issues.
Log Before Replacing
Check interface errors and link LEDs to target the fault.
Overview: Cable Problems You’ll See in the Field
Network and communication cables (Ethernet, RS232/RS485, CAN, phone lines and industrial field buses) are frequent causes of intermittent links, slow throughput, and device errors. This guide covers common faults - continuity breaks, pair swaps, impedance mismatch, crosstalk, grounding/earthing issues, and environmental damage - and gives step-by-step tests and practical South Africa-focused notes about availability and branch pickup.
Common symptoms
- Link flapping or intermittent connectivity (often physical or connector-related)
- Low throughput or errors on large transfers (impedance, shielding or duplex mismatch)
- No link at all (breaks, bad terminations or incorrect pinouts)
- Noisy or corrupted serial data (ground loops, misconnections, or faulty converters)
Tools you’ll need
- Multimeter (continuity, DC resistance)
- Cable tester (pair map and wiremap for UTP/STP)
- Time Domain Reflectometer (TDR) for long runs or professional fault locating
- Crimping tool, punch-down tool and replacement RJ45/RJ11/DB9 connectors
- Spare patch leads and a laptop with a NIC that supports link LEDs
Quick local note
If you need parts or testers in South Africa, check Communica’s collections for cables, connectors and tools. For branch pickup and stock checks use the branches page to confirm availability before travelling to Samrand or other locations: Branches & Trading Hours.
Standards and specs to keep in mind
Knowing the cabling standard helps narrow faults. For Ethernet, common categories are Cat5e, Cat6 and Cat6A - each has characteristic impedance (typically 100 ohm), crosstalk limits and maximum channel lengths. Serial and field-bus systems (RS232, RS485, CAN) have different electrical expectations; for example, RS485 expects differential pairs with proper termination.
| Cable Type | Typical Use | Key Specs |
|---|---|---|
| Cat5e / Cat6 UTP | Ethernet up to 1Gbps / 10Gbps (short) | 100 ohm, twisted pairs, length limit 100 m |
| STP / FTP | EMI-prone environments, industrial sites | Shielding to reduce crosstalk/EMI, requires proper grounding |
| RS232 / RS485 / CAN | Serial comms, industrial networks | Differential signalling (RS485/CAN), termination resistors, correct biasing |
Simple electrical checks (Ohm’s law reminder)
Use Ohm’s law and continuity tests when diagnosing: V = I × R. For example, measure resistance across a suspected short or open. Typical DC resistance for a good shorted patch lead pair is near 0 ohm; very high readings indicate a break. Use a cable tester to confirm pair continuity and wiring order.
For spare parts and different connector types browse the where to find XY RJ45SPJF-250 Connectors for IoT Applications in South Africa and Reviews of XY RJ45SPJF-250 Interface Connectors - Practical Evaluation & Buyer Notes (South Africa).
Related Connectors, Wire & Cable Products
Discover quality connectors, wire & cable products related to Troubleshooting Common Issues with Network and Communication Cables (South Africa)
Hikvision Ds-1ln5e-e/e Cat5 Utp Solid Copper Network Cable
Hikvision Ds-1ln5e-e/e Cat5 Utp Solid Copper Network Cable
Hikvision Ds-1ln6u-g Network Cable Cat6 Utp Solid Copper
Hikvision Ds-1ln6u-g Network Cable Cat6 Utp Solid Copper
Hikvision Hkv Ds-1ln6-uu Network & Communication Cable
Hikvision Hkv Ds-1ln6-uu Network & Communication Cable
Hikvision Hkv Ds-1ln6utc0 Network & Communication Cable
Hikvision Hkv Ds-1ln6utc0 Network & Communication Cable
Utp Cat6e 4pr Solid Cable Blue Cca
Utp Cat6e 4pr Solid Cable Blue Cca
Cat6a 4 Pair S/ftp 22awg High Speed Data Cable 10gb/ps Ethercat, Etherline, Ethernet, Profinet, Green Pvc Jacket Flame Retardant - 100 Ohm
Cat6a 4 Pair S/ftp 22awg High Speed Data Cable 10gb/ps Ethercat, Etherline, Ethernet, Profinet, Green Pvc Jacket Flame Retardant - 100 Ohm
Helukabel Paar-tronic -li-2ycyv Pe-insulated Stranded Data Cable Black 2x2 0.22mm
Helukabel Paar-tronic -li-2ycyv Pe-insulated Stranded Data Cable Black 2x2 0.22mm
Cabcom08f | Comms Cable 8 Core Stranded • 0.45mm2 Each • White Colour (price Per Meter)
Cabcom08f | Comms Cable 8 Core Stranded • 0.45mm2 Each • White Colour (price Per Meter)
Cab08pr,50mscr | Mylar Screened 0.5mm 8pr Grey Pvc Cable (price Per Meter)
Cab08pr,50mscr | Mylar Screened 0.5mm 8pr Grey Pvc Cable (price Per Meter)
Opx It-utp5egy3-pvc | Cat5e Utp P/cord 3 Meter- Grey
Opx It-utp5egy3-pvc | Cat5e Utp P/cord 3 Meter- Grey
Mod Cable 8w Black | Modular Cable 8 Way Black
Mod Cable 8w Black | Modular Cable 8 Way Black
Mod Cable 4w Black | Modular Cable 4 Core Line Cord Black Modular Cable 4 Core Line Cord Black
Mod Cable 4w Black | Modular Cable 4 Core Line Cord Black Modular Cable 4 Core Line Cord Black
Step-by-step troubleshooting workflow
Follow this practical sequence when you encounter network or comms issues. These steps are ordered to eliminate the most common physical causes first.
1. Replace with a known-good patch lead
Swap in a tested short patch lead. If the problem disappears, the original lead or connector is at fault. Communica stocks common pre-terminated patch leads and bulk cable if you need spares; check categories for connectors and cables: Collections.
2. Wiremap and pair-check
Use a cable tester to confirm pair order and detect split pairs. For Ethernet, verify T568A or T568B consistency on both ends. ASCII RJ45 wiring diagram (T568B):
Pin: 1 2 3 4 5 6 7 8 Colour: W-O O W-G B W-B G W-Br Br
Split pairs (pairs swapped across pins) can pass continuity but fail at high speed due to impedance and crosstalk issues.
3. Check termination and grounding
For differential buses (RS485, CAN) confirm correct termination resistors (typically 120 ohm for CAN) and that shields are grounded at one point only to avoid ground loops. For shielded Ethernet, ensure the shield is properly bonded to earth at appropriate points.
4. Look for environmental damage
Inspect for rodent damage, UV-degraded outdoor sheathing, or crushed jacket from cables run through tight conduits. Replace damaged sections; for long runs consider a TDR or a professional fault-locating service if cost-effective compared to replacement (replacement Cat6 bulk cable in South Africa can range from a few hundred to over a thousand ZAR depending on reel length - check current stock for accurate pricing).
5. Diagnose performance vs link LEDs and logs
Use switch/router interface LEDs and interface statistics (errors, CRCs, collisions) to target the fault. High error counters with low signal levels point to impedance/cable issues; sudden link drops with physical move/strain often indicate poor terminations or intermittent contact.
Examples and troubleshooting calculations
Example: You see CRC errors on a 1 Gbps link. Steps: replace patch leads with Cat6 rated leads, confirm both ends are T568B wired, test with cable tester for pair loss and length. If the run exceeds 90 m including patch leads, consider link segment replacement.
| Symptom | Likely cause | Quick fix |
|---|---|---|
| Intermittent link | Loose RJ45, damaged pair, poor crimp | Reseat/replace connector, re-terminate |
| High CRC/ packet errors | Impedance mismatch, split pairs or EMI | Swap leads, test wiring, use shielded cable if needed |
When to escalate
If a TDR shows reflections or the fault is midway through a buried or long conduit run, consider a professional site visit. For education labs, keep a few spare pre-terminated patch leads and a basic cable tester in stock to reduce downtime - these items are available from Communica’s tools and connectors categories, and you can check stock levels at the Samrand head office via the main site: Network & Communication Cable CAB02PR 50m - Reliable 50m Cable for Electronics Projects.
Sources
Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.
Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.
Frequently Asked Questions
Get answers to common questions about Connectors Wire And Cable
Why Choose Communica?
*Free Shipping
Free shipping for orders over ZAR 1,000.00.
7-Day Returns
Get a full refund if you had the product for less than 7 days.
Quick Delivery
Nationwide delivery within 2 - 4 working days.