How Do I Select a Thermal Overload Switch? A Detailed South African Guide
Learn how to choose the correct thermal overload switch. Includes current ratings, selection steps, wiring, South African application notes, and where to buy locally.

Understand Key Specs
Learn current, trip class, voltage, and mounting options for overload switches.
Step-by-Step Selection
Follow a localised process to choose the right overload switch for your application.
SA Application Notes
Includes advice on availability, lead times, and typical use cases in South Africa.
Overview: What Is a Thermal Overload Switch?
A thermal overload switch, also called a thermal overload relay, is a safety component designed to disconnect power to a load-most often a motor, compressor, or pump-when excessive current (caused by overload or mechanical jam) causes dangerous overheating. It's a core part of industrial starters, home automation panels, and maker builds, preventing both equipment damage and fire risks.
Understanding Standards and Basic Specs
Thermal overload switches react to excessive heat generated by electric current. Their main specifications are:
- Rated Current Range (e.g., 1-1.6A, 5.5-8A): must match motor FLC (Full Load Current).
- Trip Class: reflects response time (Class 10, 20, or 30, typically 10 for standard motors).
- Voltage Rating: maximum line voltage the switch can handle (often up to 690V AC).
- Mounting Style: DIN-rail, panel-mount, or direct-on-starter; check compatibility with local enclosures or MCCs.
- Reset Type: manual or automatic reset after trip - manual preferred for safety.
Specification Comparison Table
| Parameter | Application | Typical Range |
|---|---|---|
| Rated Current | Motor, compressor | 0.1 – 100A |
| Trip Class | Response speed | 10, 20, 30 |
| Reset Mode | Safety & automation | Manual / Auto |
How to Select a Thermal Overload Switch: Step-by-Step
Choosing the correct overload switch depends on understanding your load and installation. The typical process:
- Identify motor or load full-load current (FLC) from the nameplate or datasheet.
- Select a switch covering your FLC with its adjustable range.
- Match trip class (Class 10 for general motors, 20/30 for high-inertia loads).
- Check voltage and phase compatibility with your supply (e.g., 230V single-phase or 400V three-phase; most overloads are rated up to 690V AC).
- Choose reset type (manual for most safety situations).
- Verify mounting (ensure it fits your starter or enclosure; DIN-rail is common in SA).
Current Sizing Example (South Africa Context)
Suppose you have a 2.2 kW, 400V three-phase motor with a FLC of 4.8A (as found on the motor's nameplate):
- Select an overload switch with a range covering 4.8A (e.g., 4-6A).
- Set the dial to just above FLC if in dusty or hot conditions (ambient above 40 degreesC).
For local supply, check category "Circuit Protection" and use Search by Brand for product availability and regionally popular models.
Related Circuit Protection & Passive Components Products
Discover quality circuit protection & passive components products related to How Do I Select a Thermal Overload Switch? A Detailed South African Guide
Ck-100 | Thermostat • 100°c • 250v • 10a • Fixed Bracket Horizontal Lead • 19.5x6x4.2mm
Ck-100 | Thermostat • 100°c • 250v • 10a • Fixed Bracket Horizontal Lead • 19.5x6x4.2mm
Rh03b-75 | Thermal Cut-off • 75°c • 250v • 2a • Axial • 10x2.8mm
Rh03b-75 | Thermal Cut-off • 75°c • 250v • 2a • Axial • 10x2.8mm
Rh03b-150 | Thermal Cut-off • 150°c • 250v • 2a • Axial • 10x2.8mm
Rh03b-150 | Thermal Cut-off • 150°c • 250v • 2a • Axial • 10x2.8mm
Rh01-125 | Thermal Cut-off • 125°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-125 | Thermal Cut-off • 125°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-120 | Thermal Cut-off • 120°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-120 | Thermal Cut-off • 120°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-110 | Thermal Cut-off • 110°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-110 | Thermal Cut-off • 110°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-100 | Thermal Cut-off • 100°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-100 | Thermal Cut-off • 100°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-130 | Thermal Cut-off • 130°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-130 | Thermal Cut-off • 130°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-140 | Thermal Cut-off • 140°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-140 | Thermal Cut-off • 140°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh03b-100 | Thermal Cut-off • 100°c • 250v • 2a • Axial • 10x2.8mm
Rh03b-100 | Thermal Cut-off • 100°c • 250v • 2a • Axial • 10x2.8mm
Rh01-150 | Thermal Cut-off • 150°c • 250v • 2a • Radial • 6x6.5x2.8mm
Rh01-150 | Thermal Cut-off • 150°c • 250v • 2a • Radial • 6x6.5x2.8mm
Formulas and Calculations: Ensuring Accurate Protection
FLC (A) = P (kW) x 1000 / (3 x Voltage x Power Factor x Efficiency)
- Assume typical power factor of 0.8 and efficiency of 85-90% for standard induction motors.
- Example: For a 1.1kW, 400V three-phase motor:
FLC ~ 1,100 / (1.73 x 400 x 0.8 x 0.9) ~ 2.2A
Wiring & Installation Notes
Connection is usually in series with the motor contactor. In a classic three-phase control box, the wiring diagram may look as follows:
[L1]---[OLR]---+---[Contactor]---[Motor] [L2]---[OLR]---+ [L3]---[OLR]---+
Where [OLR] is the overload switch. Auxiliary NC contacts are used in the control circuit so that a trip interrupts the start relay coil.
Troubleshooting: Common Pitfalls and Solutions
- Switch trips immediately: May be set below actual FLC, or load is jammed. Confirm settings and mechanical condition.
- Switch does not trip even on jam: Dial set too high, wrong trip class chosen, or thermal element mismatch.
- Erratic tripping in hot SA climates: Consider derating or adjusting to ambient temperature above 40 degreesC.
- Oversizing: Leads to no protection; always use range as close to FLC as load variation allows.
South African Buying & Application Notes
- Availability: Popular current ranges and mounting types (especially 1-32A, DIN-rail) are readily stocked at Communica branches in Samrand (Gauteng), Cape Town, and Pretoria.
- Educational Use: Technical colleges and training facilities use small overload switches in motor starter demonstrators and PLC panels.
- Brands: ABB, Schneider, Eaton, Chint, and Lovato commonly found in South African electrical panels.
- Documentation: Always retain datasheets for wiring, trip class, and adjustment details.
Sources
Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.
Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.
Frequently Asked Questions
Get answers to common questions about Circuit Protection And Passive Components
Why Choose Communica?
*Free Shipping
Free shipping for orders over ZAR 1,000.00.
7-Day Returns
Get a full refund if you had the product for less than 7 days.
Quick Delivery
Nationwide delivery within 2 - 4 working days.