Differences Between UTP and FTP Cables for Networking in South Africa
Learn the technical and practical differences between UTP and FTP network cables. Evaluate shielding, specs, interference, pricing, and local availability for your SA networking setup.

UTP vs FTP Explained
Compare structure, shielding, and best-use scenarios for each cable type.
Selection Tips for SA Projects
Practical advice on choosing, sourcing, and installing cables locally.
Troubleshooting Essentials
How to handle noise, installation, and compatibility issues in real-world networks.
Overview: UTP and FTP Network Cables
Two of the most common cable types for Ethernet networking are UTP (Unshielded Twisted Pair) and FTP (Foiled Twisted Pair). Both are used extensively for wired LAN installations in homes, businesses, schools, and industry throughout South Africa. Understanding their structural differences, shielding methods, and correct application helps ensure reliable connectivity and compliance with network standards.
What Is UTP Cable?
UTP cables consist of twisted pairs of copper wires without any extra shielding. Popular in Cat5e, Cat6, and Cat6A categories, UTP is prized for its flexibility, ease of termination, and cost-effectiveness. These cables rely solely on balanced pair twisting to cancel out electromagnetic interference (EMI).
What Is FTP Cable?
FTP cables include a layer of foil shielding wrapped around all four pairs (overall foil screen), which provides added protection against EMI. Available in similar performance categories, FTP is used where additional noise protection is needed, such as near motors or in dense office environments. There are also variations with pair-by-pair screening (S/FTP, F/UTP), but FTP typically refers to an overall foil shield.
Comparing UTP and FTP: Technical Differences
| Feature | UTP | FTP |
|---|---|---|
| Shielding | None (just twisting) | Overall foil shield |
| Interference Protection | Moderate (suitable for low-noise areas) | Higher (reduces EMI and crosstalk) |
| Flexibility | Excellent | Slightly stiffer |
| Cost | Lower | Higher (typically +15-25%) |
| Ease of Termination | Simple (standard RJ45) | May require shielded jacks |
| Typical Uses | Home, office, general wiring | Industrial, noisy, or high-density setups |
Performance Standards and Specifications
UTP and FTP cables are manufactured according to the same core Ethernet category specifications (Cat5e, Cat6, Cat6A, etc.) and both support up to 1GbE or 10GbE speeds, depending on grade. In practice, choosing between UTP and FTP depends more on your installation environment than raw speed. Most residential and light commercial networks in South Africa rely on Cat6 UTP, while FTP is recommended for facilities near industrial equipment or longer cable runs near power lines.
Related Connectors, Wire & Cable Products
Discover quality connectors, wire & cable products related to Differences Between UTP and FTP Cables for Networking in South Africa
Ftp Cat6e 4pr Solid Uv Protected Cable Black
Ftp Cat6e 4pr Solid Uv Protected Cable Black
Cat6a Shielded Foil Twisted Pair High Speed Data Cable With Overall Braided Screen - Green Lszh Outer Jacket 23awg Conductors
Cat6a Shielded Foil Twisted Pair High Speed Data Cable With Overall Braided Screen - Green Lszh Outer Jacket 23awg Conductors
Cab04pr Ftp(cat6e)solid | Ftp Cat6e 4pr 100r Solid Grey (cca) (price Per Meter)
Cab04pr Ftp(cat6e)solid | Ftp Cat6e 4pr 100r Solid Grey (cca) (price Per Meter)
Cab04pr Utp (cat6) | Utp Cable Solid 4 Pair Cat 6 • Nominal Impedance : 100? (price Per Meter)
Cab04pr Utp (cat6) | Utp Cable Solid 4 Pair Cat 6 • Nominal Impedance : 100? (price Per Meter)
Cab04pr Utp Solid Copper Yl | Utp Cat5e 4pr 100r Solid Copper Yellow {cca} Cable (price Per Meter)
Cab04pr Utp Solid Copper Yl | Utp Cat5e 4pr 100r Solid Copper Yellow {cca} Cable (price Per Meter)
Cab04pr Ftp Solid | Ftp Cable Solid 4 Pair Cat 5 • Blue Colour • Nominal Impedance : 100? (price Per Meter)
Cab04pr Ftp Solid | Ftp Cable Solid 4 Pair Cat 5 • Blue Colour • Nominal Impedance : 100? (price Per Meter)
Cab04pr Ftp(cat5e) Solid Blk | Ftp Cat5e 4pr Shielded uv Black Solid Outdoor 100 (price Per Meter)
Cab04pr Ftp(cat5e) Solid Blk | Ftp Cat5e 4pr Shielded uv Black Solid Outdoor 100 (price Per Meter)
Cab04pr Utp Solid | Utp Cable Solid 4 Pair Cat 5 • Nominal Impedance : 100? (price Per Meter)
Cab04pr Utp Solid | Utp Cable Solid 4 Pair Cat 5 • Nominal Impedance : 100? (price Per Meter)
Cab04pr Utp Solid Copper | Utp Cable Solid Copper With 4 Pair Cat 5e In Grey Colour With Nominal Impedance : 100? (price Per Meter)
Cab04pr Utp Solid Copper | Utp Cable Solid Copper With 4 Pair Cat 5e In Grey Colour With Nominal Impedance : 100? (price Per Meter)
Cab04pr Utp Stranded | Utp Cable Stranded 4 Pair Cat 5 • Nominal Impedance : 100? (price Per Meter)
Cab04pr Utp Stranded | Utp Cable Stranded 4 Pair Cat 5 • Nominal Impedance : 100? (price Per Meter)
How to Choose the Right Cable: Practical Selection Criteria
- Assess the environment: Are there strong EMI sources (machinery, fluorescent lights, nearby high-voltage cabling)? FTP may be beneficial.
- Budget: UTP is more economical, especially for large-scale runs. Save FTP for critical segments.
- Compatibility: Shielded FTP cables often require compatible modular plugs and properly earthed shielded patch panels.
- Cable Length: For typical 90m runs under 1GbE, both UTP and FTP are suitable, but shielded cable may offer benefits over long structured backbones.
- Brand and Stock: Communica offers a large variety of network cables-including Cat5e/6 UTP and FTP-in store and online. Brands such as Amphenol and generic house brands are commonly found in SA.
Example: Cat6 Cable Selection and Installation in a School
A local high school's IT lab needed to upgrade its wiring for reliable 1Gbps speeds. For most classrooms, Cat6 UTP sufficed, but computer rooms near fluorescents and a server room close to HVAC plant were cabled using Cat6 FTP for better EMI resistance. The installer ensured shielded jacks and a properly earthed patch panel were used for FTP runs.
Installation and Handling Tips
- Avoid tight bends in both UTP and FTP cables (bend radius > 20mm for Cat6/Cat6A).
- For FTP, maintain the integrity of the foil; avoid nicking during stripping.
- Use shielded RJ45 connectors for FTP and ensure continuity of the shield to ground.
- Label all runs by cable type and termination to avoid confusion during upgrades.
Troubleshooting: Common Cable Issues
Interference, slow connections, or random disconnects can arise from cable mismatches or poor terminations. For UTP, EMI from nearby electrical cables can sometimes cause unexplained drops-relocate or switch to FTP if possible. For FTP, continuity of the foil shield to ground is essential: missed earth connections can cause even more noise problems. Always test with a cable certifier if available.
Conclusion
While UTP cables cover 90% of typical networking requirements in Southern Africa, FTP is an important tool for facilities with elevated interference or strict reliability demands. The choice should reflect your installation environment, infrastructure budget, and compatibility with terminations available locally. Always follow best practices for handling and testing to guarantee a future-ready network.
Sources
Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.
Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.
Frequently Asked Questions
Get answers to common questions about Connectors Wire And Cable
Why Choose Communica?
*Free Shipping
Free shipping for orders over ZAR 1,000.00.
7-Day Returns
Get a full refund if you had the product for less than 7 days.
Quick Delivery
Nationwide delivery within 2 - 4 working days.




















