Overview: Why the Shielding Question Matters
RJ45 connectors are the mechanical link between Ethernet cabling and your devices. The primary choice for installers and makers is between shielded RJ45 connectors (often labelled STP/FTP for the cable) and unshielded RJ45 connectors (UTP). This decision affects electromagnetic compatibility (EMC), grounding, cable management, and installation technique - all important for South African makers, students, and technicians working with industrial equipment, PoE cameras, or dense wiring in labs.
Key terms
- Shielded connector: includes a metal shell or drain-wire termination to maintain a continuous shield to cable screen.
- Unshielded connector: plastic body with no intentional connection to cable screen; simpler and cheaper to terminate.
- Category rating: Cat5e/Cat6/Cat6A etc. matters for conductor geometry and impedance; choose matching connectors and jacks.
Where this guide helps
This guide explains practical selection criteria, termination tips, performance trade-offs, a wiring diagram, a comparison table, and local buying considerations including lead times and branch pickup at Communica branches. For a quick look at product ranges, see the Collections index and the Shop by Brand page to find familiar makers like Amphenol and Molex.
Standards, Specs and Electrical Basics
Both shielded and unshielded RJ45 connectors are used across Cat5e, Cat6 and Cat6A systems. The electrical behaviour you care about typically includes characteristic impedance (100 Ohm nominal for Ethernet twisted pair), return loss, and near-end crosstalk (NEXT). Connectors designed for higher category cabling will better preserve those parameters when terminated correctly.
| Parameter | Impact of Shielding | Practical Note |
|---|---|---|
| EMI/RFI Immunity | Improved with continuous shield and correct grounding | Useful near motors, radios, or dense power cabling |
| Grounding Requirement | Shield must be bonded to protective earth at one or both ends | Improper bonding can create ground loops and noise |
| Cost & Complexity | Higher cost and more skill to terminate | Consider for industrial or long runs; UTP fine for home/office |
Simple electrical check (example)
If you suspect EMI on a 100 m Ethernet run, measure differential signal integrity with a cable tester that reports attenuation. Rough rule: each additional dB of unwanted noise reduces SNR; for PoE systems, ensure the shield does not carry current paths that affect the pair voltages. For component choices and tools, explore the how-to-install-shielded-rj45-connectors index to find testers and termination kits.
Selection Criteria: When to Use Shielded vs Unshielded
- Electrically noisy environments: prefer shielded connectors and screened cable, provided you can ground correctly.
- Short indoor office/home runs: unshielded (UTP) usually suffices and is easier for students and makers.
- Outdoor or exposed installations: use appropriate outdoor-rated cable and consider shield continuity to minimise ingress; also use suitable connectors rated for environmental exposure.
- High-speed links (10G over Cat6A): use connectors and cables specified for the target category; many Cat6A installs use shielded systems to control alien crosstalk on tightly packed cables.
Local tip: for many South African student labs and maker spaces, UTP Cat6 terminated with reliable RJ45 plugs provides excellent balance of performance and cost. For factory floors or near elevator motors, consult a shielded solution and check branch stock and lead times at our ip67-rated-rj45-connectors-for-outdoor-use page before starting large runs.
Related Connectors, Wire & Cable Products
Discover quality connectors, wire & cable products related to Shielded vs Unshielded RJ45 Connectors: A Practical Comparison for South African Projects
Adaptor Hdmi-female To Hdmi(micro)-male + Hdmi(mini)-male T-shape Gold Plated Contacts In Black
Adaptor Hdmi-female To Hdmi(micro)-male + Hdmi(mini)-male T-shape Gold Plated Contacts In Black
Adaptor Hdmi-female To Hdmi(micro)-male Straight Gold Plated Contacts In Black
Adaptor Hdmi-female To Hdmi(micro)-male Straight Gold Plated Contacts In Black
Adaptor Hdmi-female To Hdmi(micro)-male 90° Upright Gold Plated Contacts In Black
Adaptor Hdmi-female To Hdmi(micro)-male 90° Upright Gold Plated Contacts In Black
Adaptor Dvi (m) 25p To Hdmi A(f)
Adaptor Dvi (m) 25p To Hdmi A(f)
Adaptor Hdmi-male To Dvi-male With 25 Pin Gold Plated Contacts In Black
Adaptor Hdmi-male To Dvi-male With 25 Pin Gold Plated Contacts In Black
Adaptor Usb(3.0)-male To Usb-female Straight
Adaptor Usb(3.0)-male To Usb-female Straight
Adaptor Hdmi-male To Hdmi-female Right Side Flat 90° Gold Plated Contacts In Black
Adaptor Hdmi-male To Hdmi-female Right Side Flat 90° Gold Plated Contacts In Black
Termination and Installation Best Practices
Shielded terminations require consistent attention to the cable shield, drain wire, and connector body. Poor terminations can negate shielding benefits or create ground loops. Unshielded terminations focus on pair order, conductor untwist length, and reliable contact pressure.
Typical RJ45 wiring (T568B) - ASCII diagram
Pin: 1 2 3 4 5 6 7 8 Colour: OR WH OR GN WH GN BL WH BL
Keep untwist length under 13 mm where possible for best signal integrity. For shielded plugs, fold the drain wire over the connector shield and ensure the metal shell is seated before crimping.
Troubleshooting common issues
- Intermittent link after termination: check conductor seating, crimp tool calibration, and untwist length.
- Persistent noise despite shielded cable: verify shield bonding to earth and avoid multiple disjointed ground points creating loops.
- Link speed falls to 100 Mbps or 10 Mbps: check pair integrity and confirm the connector and cable are rated for the intended category.
Example: Choosing connectors for a 60 m PoE camera run
Scenario: a 60 m run near fluorescent ballasts and a small VFD. Options:
- Use shielded Cat6 cable with shielded RJ45 plugs and bond shield to single-point earth at the switch end. This reduces EMI risk and preserves PoE stability.
- If grounding is not feasible, route unshielded Cat6 away from noise sources or use fibre for the noisy segment.
Product and Local Buying Notes
Communica stocks a wide range of connectors, boots, shielded plugs, and termination tools suitable for Cat5e-Cat6A projects. When planning procurement, check stock at the Samrand head office or other branches, compare brands and termination styles, and request VAT invoices for institutional or education purchases. See Communica’s homepage for an overview of ranges and services: Communica homepage.
Accessories and tools to consider
- Quality crimp tool rated for the connector style
- Cable testers that report pair continuity, crosstalk or wiremap
- Shielded boots and strain reliefs for outdoor or exposed connectors
Summary: Practical Recommendation
For most South African home, education, and maker projects, unshielded Cat6 RJ45 connectors provide the best balance of cost, ease of use, and performance. Choose shielded connectors when installing near strong EMI sources, for long runs in industrial settings, or when using Cat6A at higher data rates. Plan for proper grounding and use the right tools to preserve category performance. For further browsing, the product collections and brand pages can help you match connectors, plugs and tools to your project needs: How to Install Shielded RJ45 Connectors - Step-by-Step Guide (South Africa), IP67 Rated RJ45 Connectors for Outdoor Use - Weatherproof Ethernet Solutions, and the RJ45 Shielded Waterproof Panel Jack - Angled Feed-Thru Receptacle page for company background and branch information.
Sources
Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.
Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.
Frequently Asked Questions
Get answers to common questions about Connectors Wire And Cable
Why Choose Communica?
*Free Shipping
Free shipping for orders over ZAR 1,000.00.
7-Day Returns
Get a full refund if you had the product for less than 7 days.
Quick Delivery
Nationwide delivery within 2 - 4 working days.