Fuse for Overcurrent

Place a fuse at the input; choose time-delay for inrush. Use 125-150% of max current.

PTC for Resettable Protection

Use PTCs for low-voltage logic lines; they reset after fault and have low voltage ratings.

TVS for Overvoltage Clamping

Place TVS diodes near connectors or ICs; choose standoff voltage above operating level.

Why Circuit Protection Placement Matters as Much as the Component Itself

Selecting the right circuit protection device is only half the battle. Where you place it in the schematic, how you route the PCB tracks around it, and how you coordinate different protection stages can mean the difference between a device that survives a transient and one that lets the magic smoke out. In my years of troubleshooting failed prototypes and production boards, I've seen more failures caused by poor placement than by undersized components. This guide focuses on the practical decisions-the 'where' and 'why'-that transform a parts list into a reliable protection scheme.

For South African makers and engineers, the challenge is often compounded by stock availability and lead times. You might design with a specific fuse or TVS diode in mind, only to find it's not locally stocked. Understanding the function of each protection device-and how to substitute a similar part-becomes crucial. In this guide, we'll walk through the three most common discrete protection devices: fuses, PTC resettable fuses, and TVS diodes, and we'll look at placement strategies that work on real boards.

Note: This is a selection and placement guide, not a comprehensive standards reference. Always verify component specifications against the datasheet and your application's operating conditions.

Understanding the Role of Each Protection Device

At their core, circuit protection devices are designed to either interrupt current (fuses and PTCs) or clamp voltage (TVS diodes). They handle two different threats: overcurrent and overvoltage. A motor stall or a shorted load causes overcurrent; an inductive spike from a relay coil or ESD from a human touch causes overvoltage. The right protection scheme combines both types, placed at the appropriate points in the circuit.

Fuses: The Sacrificial Sentinel

Fuses are one-shot devices. When current exceeds their rating, a fusible element melts and opens the circuit. They are simple, reliable, and come in many package types-from glass cartridge fuses to surface-mount chip fuses. Key specs are current rating, voltage rating, and interruption rating (the maximum fault current they can safely break). For example, a 5×20mm glass fuse rated at 1A and 250VAC is common in benchtop supplies.

In selecting a fuse, consider the normal operating current. A common rule of thumb is that the fuse rating should be 125% to 150% of the maximum steady-state current, accounting for ambient temperature and inrush. For instance, if your motor draws 2A under load, a 3A fuse is a safe starting point. But watch for inrush-capacitors charging can produce a brief pulse that shouldn't open the fuse. A time-delay (slow-blow) fuse handles this better.

PTC Resettable Fuses: The Reusable Protector

PTCs (positive temperature coefficient) are resettable devices. Under normal operation, they have very low resistance. When overcurrent flows, they heat up, and their resistance dramatically increases-limiting current to a safe level. Once the fault is removed and the device cools, it resets to low resistance. This makes them ideal for situations where you don't want to replace a fuse after every fault-like in hobbyist projects, USB ports, or battery packs.

For a hobby circuit, a PTC like the set of a 500mA PTC used in series with the power input is a low-cost safeguard. Key specs: hold current (the current it carries without tripping), trip current (the level that causes it to trip), and maximum voltage (e.g., 16V or 30V for common PTCs). Remember that PTCs are not precise-their resistance changes with temperature, so they are not suitable for precision current limiting. They also have a maximum voltage rating; don't use them in mains-voltage circuits above their rated voltage.

TVS Diodes: Transient Voltage Surge Suppressors

TVS diodes are avalanche diodes designed to clamp overvoltage transients. They are fast-responding in picoseconds-making them ideal for ESD and inductive spikes. They are specified by their standoff voltage (the maximum voltage they allow to pass without conducting), breakdown voltage (where they start conducting), and peak pulse power rating (how much energy they can absorb). For a 5V digital line, a TVS with a standoff voltage of 5V and a breakdown around 6V is common.

In practice, TVS diodes are used in two ways: as unidirectional components for DC lines (cathode to VCC, anode to GND) or bidirectional for AC signals. Place them as close to the connector or the vulnerable IC as possible, with short leads to minimize inductance.

Related Circuit Protection & Passive Components Products

Discover quality circuit protection & passive components products related to Circuit Protection Devices for Electronics: How to Select and Place Fuses, PTCs, and TVS Diodes

8a Cer 6x32 S/b | Ceramic Fuse • Slow Blow • 8a • 6ø X 32mm

8a Cer 6x32 S/b | Ceramic Fuse • Slow Blow • 8a • 6ø X 32mm

CommunicaFuses
ZAR5.46

8a Cer 6x32 S/b | Ceramic Fuse • Slow Blow • 8a • 6ø X 32mm

8a Cer 6x32 F/b | Ceramic Fuse • Fast Blow • 8a • 6ø X 32mm

8a Cer 6x32 F/b | Ceramic Fuse • Fast Blow • 8a • 6ø X 32mm

CommunicaFuses
ZAR5.29

8a Cer 6x32 F/b | Ceramic Fuse • Fast Blow • 8a • 6ø X 32mm

8a Cer 5x20 S/b | Ceramic Fuse • Slow Blow • 8a • 5ø X 20mm

8a Cer 5x20 S/b | Ceramic Fuse • Slow Blow • 8a • 5ø X 20mm

CommunicaFuses
ZAR4.26

8a Cer 5x20 S/b | Ceramic Fuse • Slow Blow • 8a • 5ø X 20mm

8a Cer 5x20 F/b | Ceramic Fuse • Fast Blow • 8a • 5ø X 20mm

8a Cer 5x20 F/b | Ceramic Fuse • Fast Blow • 8a • 5ø X 20mm

CommunicaFuses
ZAR4.03

8a Cer 5x20 F/b | Ceramic Fuse • Fast Blow • 8a • 5ø X 20mm

8a 6x32 S/b | Glass Fuse • Slow Blow • 8a • 6.3Ø X 32mm

8a 6x32 S/b | Glass Fuse • Slow Blow • 8a • 6.3Ø X 32mm

CommunicaFuses
ZAR3.39

8a 6x32 S/b | Glass Fuse • Slow Blow • 8a • 6.3Ø X 32mm

8a 6x32 F/b | Glass Fuse • Fast Acting • 8a • 6.3Ø X 32mm

8a 6x32 F/b | Glass Fuse • Fast Acting • 8a • 6.3Ø X 32mm

CommunicaFuses
ZAR3.28

8a 6x32 F/b | Glass Fuse • Fast Acting • 8a • 6.3Ø X 32mm

8a 5x20 S/b | Glass Fuse • Slow Blow • 8a • 5Ø X 20mm

8a 5x20 S/b | Glass Fuse • Slow Blow • 8a • 5Ø X 20mm

CommunicaFuses
ZAR3.00

8a 5x20 S/b | Glass Fuse • Slow Blow • 8a • 5Ø X 20mm

8a 5x20 F/b | Glass Fuse • Fast Acting • 8a • 5Ø X 20mm

8a 5x20 F/b | Glass Fuse • Fast Acting • 8a • 5Ø X 20mm

CommunicaFuses
ZAR2.42

8a 5x20 F/b | Glass Fuse • Fast Acting • 8a • 5Ø X 20mm

80ma 6x32 S/b | Glass Fuse • Slow Blow • 80ma • 6.3Ø X 32mm

80ma 6x32 S/b | Glass Fuse • Slow Blow • 80ma • 6.3Ø X 32mm

CommunicaFuses
ZAR5.23

80ma 6x32 S/b | Glass Fuse • Slow Blow • 80ma • 6.3Ø X 32mm

80ma 6x32 F/b | Glass Fuse • Fast Acting • 80ma • 6.3Ø X 32mm

80ma 6x32 F/b | Glass Fuse • Fast Acting • 80ma • 6.3Ø X 32mm

CommunicaFuses
ZAR3.70

80ma 6x32 F/b | Glass Fuse • Fast Acting • 80ma • 6.3Ø X 32mm

80ma 5x20 S/b | Glass Fuse • Slow Blow • 80ma • 5Ø X 20mm

80ma 5x20 S/b | Glass Fuse • Slow Blow • 80ma • 5Ø X 20mm

CommunicaFuses
ZAR3.68

80ma 5x20 S/b | Glass Fuse • Slow Blow • 80ma • 5Ø X 20mm

80ma 5x20 F/b | Glass Fuse • Fast Acting • 80ma • 5Ø X 20mm

80ma 5x20 F/b | Glass Fuse • Fast Acting • 80ma • 5Ø X 20mm

CommunicaFuses
ZAR4.03

80ma 5x20 F/b | Glass Fuse • Fast Acting • 80ma • 5Ø X 20mm

Placement Strategies: Where to Put Each Device in Your Schematic

Now that we know what each device does, let's talk about placement. The goal is to protect the circuits that matter, without introducing unnecessary resistance or noise.

Series vs. Shunt Placement

Fuses and PTCs are series elements-they sit in the current path. TVS diodes are shunt elements-they connect from the line to ground. In a typical power input circuit, the order is: input connector → fuse/PTC → TVS diode → (optional filter) → regulator.

Placing the fuse or PTC right at the input prevents any downstream short from drawing excessive current. The TVS diode should be placed after the fuse but before the regulator, to clamp any voltage spike that gets through. Why after the fuse? If a massive transient arrives, the TVS will conduct and potentially trip the fuse-but that's a safe failure mode, protecting the regulator.

Protecting Digital Lines and Sensor Inputs

For digital lines like I2C, SPI, or GPIO, a TVS diode or a clamp circuit is the norm. Place the TVS as close as possible to the connector-every millimetre of trace from the connector to the TVS acts as an antenna and adds inductance that can defeat the clamping. Use a low-capacitance TVS for high-speed signals to avoid signal degradation.

For analog sensor inputs, consider a PTC in series with the line and a TVS to ground. This combination limits both current and voltage, protecting the ADC input of your microcontroller.

A Practical Example: Protecting a 12V DC Motor Controller

Let's design a simple protection scheme for a 12V DC motor controller using a relay. The motor draws 3A at stall. Our controller uses a MOSFET or a relay to switch the motor. The threats: overcurrent if the motor jams, and voltage spikes from the motor's inductance when switched off.

  • Fuse: Place a 5A time-delay fuse in the main 12V line before the motor driver. This allows inrush without nuisance trips but opens on a sustained stall.
  • TVS: Place a unidirectional TVS (e.g., SMBJ12A, standoff 12V, breakdown 13.3V) across the motor terminals, or a flyback diode (a regular diode like 1N4007) if it's a relay. For simpler designs, a flyback diode is cheaper-use a TVS when you need faster response or when dealing with PWM signals.
  • PTC for the control logic: Place a 100mA PTC in series with the microcontroller's power line (if separate). This protects the logic supply without a fuse that needs replacement.

This arrangement uses all three device types in their ideal roles: fuse for main power, TVS for inductive spike clamping, and PTC for low-power logic protection.

Common Mistakes and How to Avoid Them

  • Placing a fuse after the regulator: The upstream section remains unprotected. Always fuse the primary input.
  • Using a PTC in a high-voltage circuit: PTCs have low voltage ratings (typically ≤30V). Check the datasheet-using a 16V PTC on 24V is a fire hazard.
  • Ignoring inrush current: A fast-blow fuse might open on capacitor charging. Choose time-delay fuses for capacitive loads.
  • Putting a TVS in series with the load: TVS must be in shunt to ground; in series, it blocks voltages above its breakdown, cutting off the load.
  • Selecting too large a hold current PTC: The PTC won't trip early enough-the circuit may be damaged before it reacts.

When in doubt, simulate your circuit with the protection components in place using a tool like LTspice. Many TVS and fuse models are available, and you can check the behavior under transient conditions.

Selection Criteria: Balancing Protection with Practicality

Now let's talk about what to look for when browsing components, especially locally. In South Africa, you'll often encounter common part numbers from manufacturers like Bourns, Littelfuse, and Vishay. These are reliable brands, and Communica stocks a broad range of circuit protection devices from these makers. When selecting a part, follow this checklist:

  • Determine the threat: Overcurrent? Overvoltage? Both?
  • Specify the parameters: For a fuse: max steady-state current, max operating voltage, ambient temperature, inrush profile. For a TVS: working voltage, peak pulse power, package type. For a PTC: hold current, trip current, max voltage.
  • Choose the package: Through-hole (easier for breadboards and hand-soldering) vs SMD (for production). For prototypes, through-hole is more practical.
  • Consider resettability: If you're prototyping, use PTCs for power inputs-you won't have to replace fuses after accidental shorts.
  • Check availability and lead time: A datasheet part number doesn't help if it's a 12-week backorder. Have a few alternates in mind.

For a typical hobby project, a 5×20mm ceramic fuse with a 5A rating costs about R30-R60 at local retailers. A PTC like a 500mA/16V device is in the same range. A TVS diode in an SMB package is usually under R20. Budget accordingly.

Common Part Numbers and Specifications

To help you get started, here are a few common devices you'll find in local distributors, with typical specs. Always verify the exact specifications and substitutes on the product page or datasheet.

DeviceTypeKey SpecsTypical Use
5×20mm fuse, 1AFuse1A, 250VAC, fast or time-lagBenchtop PSU, mains input
PTC 500mAResettable fuseHold 0.5A, trip 1A, 16VUSB ports, Arduino shields
SMBJ5.0ATVS unidirectionalStandoff 5V, breakdown 6.4V, 600W peakProtect 5V logic lines
P6KE30CATVS bidirectionalStandoff 30V, 600W peak24V systems, relay outputs

For more options, browse the full range of circuit protection components at Communica.

Schematic Design Patterns for Robust Protection

Designing protection into your schematic is about layering. A single protection device cannot handle every threat; you need a hierarchy. A typical order:

  1. First line: At the power input, place a fuse or PTC to limit overcurrent.
  2. Second line: After the fuse, place a TVS diode (or varistor) to clamp voltage transients.
  3. Third line: For sensitive ICs, add a series resistor (or PTC) to limit current, and a local TVS or ESD diode at the IC's power pin.

In a multi-stage design, remember that each stage must handle the energy that reaches it. If the TVS clamps a large surge, it may pass a large current back through the fuse, which may then open. That's a coordinated response-the TVS absorbs the spike, and the fuse clears the overcurrent.

Testing Your Protection Scheme

Once you've assembled your board, you should test the protection. Use a bench power supply with current limiting. First, power the circuit normally and verify no spurious trips. Then, intentionally short the output (or introduce a fault) for a brief moment to see if the fuse/PTC trips. For TVS, you may not want to test with mains, but you can simulate a transient with a capacitor discharge circuit (once you're experienced). Always have the datasheets handy to know what to expect.

Sources

Communica Samrand — Electronic Component Experts

Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.

Last updated: August 18, 2026

Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.

Frequently Asked Questions

Get answers to common questions about Circuit Protection And Passive Components

Why Choose Communica?

*Free Shipping

Free shipping for orders over ZAR 1,000.00.

7-Day Returns

Get a full refund if you had the product for less than 7 days.

Quick Delivery

Nationwide delivery within 2 - 4 working days.