Learn how to choose the right wire and cable for electronics: conductor types, AWG/mm² sizing, insulation, shielding, and practical South African buying notes.

Size for Current
Choose conductor area by continuous and peak current plus headroom.
Insulation & Flex
Pick silicone for flex, PTFE for heat, PVC for general use.
Reduce Voltage Drop
Shorter runs or larger conductors cut losses and heat.
Overview: Why cable choice matters
Selecting the right wire or cable affects voltage drop, heat, mechanical reliability, and signal integrity. For hobby and professional electronics - from breadboard wiring to motor harnesses and PCB-to-terminal runs - the conductor material, strand count, insulation, and cross-sectional area determine performance. This guide walks through selection criteria, simple calculations, wiring examples, and local buying notes relevant to South African builders and procurement teams.
Key terms and conductor types
Conductor materials
Copper is the default for electronics because of its low resistivity and availability. You will encounter plain annealed copper, tinned copper (better for soldering and corrosion resistance), and occasionally copper-clad aluminium (CCA) in low-cost cables - CCA has higher resistance and is not ideal for high-current runs.
Solid vs stranded
Solid wire (single core) is stiffer and good for PCB connections and fixed wiring. Stranded wire is flexible and better for moving parts, breadboards, and enclosures. Higher strand counts improve flexibility but slightly increase cost.
Insulation types and typical uses
- PVC: economical, common for internal wiring, but stiffer and less heat-resistant.
- Silicone rubber: very flexible and heat-resistant; ideal for high-flex or small robotic joints.
- PTFE (Teflon): excellent thermal and chemical resistance; used in demanding labs and high-temperature applications.
- XLPE / PE: used in power cables and where dielectric properties matter.
Standards of size: AWG and metric equivalents
In South Africa you will commonly see metric cross-sectional area (mm2) for power and AWG for some hobby cables and international datasheets. Match the size to current and acceptable voltage drop.
| AWG | Cross-section mm2 | Typical use |
|---|---|---|
| 22 AWG | 0.32 mm2 | Signal, small sensors, breadboard jumpers |
| 20 AWG | 0.52 mm2 | USB power leads, small motors |
| 16 AWG | 1.31 mm2 | Heaters, higher-current peripherals |
| 12 AWG | 3.31 mm2 | Mains or heavy power leads in projects |
Practical selection rule
Start from expected continuous current and choose a cross-section with margin (25-50% depending on ambient temperature and installation). For example, typical USB-powered boards draw under 1-2 A (22-20 AWG acceptable); small motors and servos often need 16-18 AWG for short runs.
When choosing cable from stock, explore the wire and cable categories at Electrical Connectors - Buy Online in South Africa | Communica to match conductor and insulation types to your application.
Basic calculations: resistance, voltage drop, and power loss
Ohm's law and resistance
Ohm's law: V = I × R. Use the conductor resistance (R) to estimate voltage drop and heating. For a given conductor length, R = rho × length / area, but practical tables or manufacturer datasheets are easier for quick decisions.
Voltage drop (single conductor): Vdrop = I × R. For a round-trip (supply + return) double the length or multiply by 2 in calculations.
Worked example
Example: 3 m one-way run feeding a 5 V motor drawing 3 A. Using approximate resistance for 22 AWG (53 m?/m): round-trip length = 6 m, R = 0.053 ?/m × 6 m = 0.318 ?. Vdrop = 3 A × 0.318 ? = 0.954 V (?19% of 5 V) - unacceptable; choose 18 AWG (20 m?/m) ? R ? 0.12 ? ? Vdrop = 0.36 V (7.2%) which is much better.
Power loss and heating
Power dissipated in cable: P = I^2 × R. In the example above with 0.12 ?, P = 3^2 × 0.12 ? 1.08 W - consider ventilation or larger size for continuous runs.
For measurements and lab work, pair cable choice with appropriate test equipment from Communica's test and measurement range; see the full site for relevant tools at Electrical Connectors - Buy Online in South Africa | Communica.
Related Connectors, Wire & Cable Products
Discover quality connectors, wire & cable products related to How to Choose the Best Wire and Cable for Electronics Projects (South Africa)
Communica Cab01-1,5mblu Hook Up Wire
Communica Cab01-1,5mblu Hook Up Wire
Communica Cab01-1,0ssbk Hook Up Wire
Communica Cab01-1,0ssbk Hook Up Wire
Hook Up Cable 0,5mm 14cu Strand White Black Stripe 600/1000v
Hook Up Cable 0,5mm 14cu Strand White Black Stripe 600/1000v
Hookup Cable Multi Strand • 0.22mm2 24-awg • 300v
Hookup Cable Multi Strand • 0.22mm2 24-awg • 300v
Panel Wire Multi Strand • 6mm2 • Red Colour (price Per Meter)
Panel Wire Multi Strand • 6mm2 • Red Colour (price Per Meter)
Panel Wire Multi Strand • 6mm2 • Black Colour (price Per Meter)
Panel Wire Multi Strand • 6mm2 • Black Colour (price Per Meter)
Panel Wire Multi Strand • 2.5mm2 • Yellow Colour (price Per Meter)
Panel Wire Multi Strand • 2.5mm2 • Yellow Colour (price Per Meter)
Panel Wire Multi Strand • 2.5mm2 • Red Colour (price Per Meter)
Panel Wire Multi Strand • 2.5mm2 • Red Colour (price Per Meter)
Panel Wire Multi Strand • 2.5mm2 • Green Colour
Panel Wire Multi Strand • 2.5mm2 • Green Colour
Panel Wire Multi Strand • 2.5mm2 • Green/yellow Colour
Panel Wire Multi Strand • 2.5mm2 • Green/yellow Colour
Panel Wire Multi Strand • 2.5mm2 • Grey Colour
Panel Wire Multi Strand • 2.5mm2 • Grey Colour
Panel Wire Multi Strand • 2.5mm2 • Orange Colour
Panel Wire Multi Strand • 2.5mm2 • Orange Colour
Signal cables and shielding
For data and analogue signals, minimise noise with twisted pair, shielding, or coaxial constructions. Twisted pair reduces common-mode interference; adding an overall shield (braid or foil) helps where nearby motors or mains wiring create EMI.
Recommended practices
- Keep power and signal runs separate where possible.
- Use shielded cable for long analogue sensor lines or high-speed digital links.
- Terminate shields correctly at one end or both ends depending on grounding strategy.
Mechanical and environmental considerations
Consider abrasion resistance, flex life, and temperature range. For robotics or wearable projects choose high-flex silicone or fine-stranded PVC rated for repeated bending. For outdoor or workshop use, pick UV- and oil-resistant jackets and, if needed, glanded terminations in enclosures.
Wiring examples and ASCII diagrams
Simple DC motor feed (recommended conductor sizing)
Battery + -----[ 12V ]-----+----( 16 AWG )----+---- Motor +
| |
GND Motor -
| |
Battery - ----------------+----( 16 AWG )----+-----------------
Use fused, short, and robust connectors for motor connections; stranded tinned wire improves soldering and terminal reliability.
Troubleshooting common wiring issues
Symptoms and fixes
- Voltage sag under load: check for undersized conductors or poor crimp/solder joints.
- Intermittent signals: inspect for broken strands, damaged insulation, or poor shielding.
- Excessive heat in cable: reduce current, increase conductor size, or improve ventilation.
Local note: availability and lead times vary by brand and stock. Check branch collection options and trading hours at Communica branches & trading hours to reserve common wire sizes or to collect same-day where possible.
Buying checklist and practical tips
- Identify continuous current and peak/inrush currents.
- Decide flexibility: choose stranded for moving parts and solid for PCB terminations.
- Select insulation for temperature and chemical exposure (silicone for heat, PTFE for extreme cases).
- Prefer tinned copper for soldering and corrosion resistance in humid environments.
- Label both ends of longer runs, and use colour coding for common voltages in your projects.
If you want to compare brands and specific cable constructions, use the Shop by Brand index to find options and datasheets: Electrical Connectors - Buy Online in South Africa | Communica. For bulk or education purchases, check stocklists and request VAT invoicing or quotes via the main Communica site: Buy 1-Port RS485 to Ethernet Converter in South Africa - Reliable Serial to LAN Solutions. You can also find suitable electrical connectors for motor and power connections at Electrical Connectors - Buy Online in South Africa | Communica.
Sources
- AWG (American Wire Gauge) reference - Wikipedia
- Voltage drop calculator and conductor resistivity - Engineering Toolbox
- Communica company background and branch network
- Cable selection guidance - RS or similar electronics distributors
Practical tip: when in doubt, choose the next larger conductor size and use short, high-quality connectors. For education and maker labs, buying metre-heads of common sizes (22, 20, 18, 16 AWG) covers most prototyping needs and keeps lead times short.
Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.
Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.
Frequently Asked Questions
Get answers to common questions about Connectors Wire And Cable
Why Choose Communica?
*Free Shipping
Free shipping for orders over ZAR 1,000.00.
7-Day Returns
Get a full refund if you had the product for less than 7 days.
Quick Delivery
Nationwide delivery within 2 - 4 working days.