Communica

BACnet MS/TP Modules For Sale in South Africa - Stocked Locally at Communica

Find BACnet MS/TP modules for building automation, gateways, and expansion at Communica. Local stock, branch pickup, bulk procurement and leading brands available.

cctv
July 12, 2026
3 min read

Extensive BACnet MS/TP Range

Modules for integration, retrofitting, and automation from leading brands.

Local Stock & Fast Pickup

Check current availability and collect from Samrand, Pretoria, or Cape Town.

Technical Selection Support

Guidance on compatibility, wiring, and protocol options for your BMS build.

BACnet MS/TP Modules Available at Communica

BACnet MS/TP (Master-Slave/Token Passing) modules are essential components for building management and automation systems (BMS), enabling reliable communication across HVAC, lighting, and access control networks. Communica stocks a wide selection of BACnet MS/TP interface, gateway, and I/O expansion modules suitable for new and retrofit applications in commercial, industrial, and educational facilities across South Africa.

What Is BACnet MS/TP?

BACnet MS/TP is a widely adopted BACnet communication standard using RS-485 twisted pair networks for peer-to-peer device communication at speeds typically ranging from 9600 to 115200 baud. MS/TP modules allow integration of third-party devices, expansion of I/O, or connection of multiple controllers within a distributed BMS system.

Product Options Stocked Locally

Communica's curated range features:

  • MS/TP Interface Cards for PLCs and microcontrollers
  • BACnet Gateways (MODBUS RTU <-> BACnet MS/TP, or TCP/IP <-> MS/TP)
  • I/O Expansion Modules (digital/analogue)
  • Ready-made controller expansion boards for OEM and panel builders

Leading products include reliable brands like Siemens, Advantech, Schneider, and Waveshare. Stock levels, lead times, and bulk pricing are updated daily.

Key Specification Table

Model/Brand Protocol Ports Baud Rate Mounting
Waveshare BACnet MS/TP HAT BACnet MS/TP, RS-485 1 x RS-485 9600-115200 Raspberry Pi/ DIN-rail
Advantech BEMG-4220 BACnet MS/TP 2 x RS-485 Up to 38400 DIN-rail/Mounting Plate
Siemens TX-I/O BACnet Module BACnet MS/TP 1 x RS-485 9600/38400 DIN-rail

Review datasheets or consult with Communica's specialists for detailed wiring and integration considerations for your application. Most models are compatible with standard RS-485 cabling and screw terminal or pluggable connectors found in local panel builds.

SA Context: BACnet MS/TP modules are in demand for greenfield smart buildings and BMS upgrades. Lead times for uncommon variants range 2-6 weeks. Many popular cards and gateways are available ex-stock at Samrand for direct collection or courier.

Related Security, Access Control & Surveillance Products

Discover quality security, access control & surveillance products related to BACnet MS/TP Modules For Sale in South Africa - Stocked Locally at Communica

Bacnet Ms/tp Digital I/o Module With 4 Digital Inputs And 2 Relay Outputs With Manual Control Was Developed For Decentralized Switching Tasks. (110883

Bacnet Ms/tp Digital I/o Module With 4 Digital Inputs And 2 Relay Outputs With Manual Control Was Developed For Decentralized Switching Tasks. (110883

Metz ConnectIndustrial Automation
ZAR5632.70

Bacnet Ms/tp Digital I/o Module With 4 Digital Inputs And 2 Relay Outputs With Manual Control Was Developed For Decentralized Switching Tasks. (110883

Selecting the Right BACnet MS/TP Module

  • Confirm protocol compatibility (MS/TP only vs. multimode BACnet/Modbus).
  • Check port requirements: number of RS-485 ports and isolation for noisy environments.
  • Speed support: Most devices in SA run 9600-38400 baud; some newer models support higher speeds for faster polling.
  • Mounting and form factor: DIN-rail preferred in local panels; HATs for Raspberry Pi/embedded builds.
  • Power supply voltage: Many modules operate at 12-24V DC for direct panel integration.

Example Wiring (Typical RS-485 Daisy Chain)

[Controller]---[MS/TP Module #1]---[MS/TP Module #2]---[MS/TP Module #3]
    |               |                   |                  |
  (A+, B-, GND)   (A+, B-, GND)      (A+, B-, GND)       ...

Pay attention to network biasing, 120Ohm terminations at both ends, and use shielded twisted-pair cable (standard in BMS). Always refer to the product manual for pinout and configuration details.

Popular Uses in South Africa

  • Connecting legacy HVAC controllers in shopping centres or office parks
  • Expanding IO for energy metering in university buildings
  • Integration of third-party sensors and actuators in automation projects

Procurement, Stock, and Support

Sources

Communica Samrand — Electronic Component Experts

Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.

Last updated: July 12, 2026

Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.

Frequently Asked Questions

Get answers to common questions about Security Access Control And Surveillance

Why Choose Communica?

*Free Shipping

Free shipping for orders over ZAR 1,000.00.

7-Day Returns

Get a full refund if you had the product for less than 7 days.

Quick Delivery

Nationwide delivery within 2 - 4 working days.