Communica

AXE007M2 Supplier in South Africa - Reliable Local Stock & Technical Support

Find AXE007M2 relays in South Africa at Communica - local stock, technical advice, VAT invoicing, and easy collection from Samrand, Pretoria & Cape Town branches.

electronic component fuses
June 12, 2026
3 min read

Local AXE007M2 Stock

Fast supply from Communica branches to reduce downtime.

Technical Guidance

Get relay specs, equivalents, and wiring help for projects.

Easy Quotes & Collection

Request VAT quotes, check availability, and collect locally.

AXE007M2 Relay - Overview & Applications

The AXE007M2 is a compact, general-purpose electromechanical relay commonly used in control panels, PLC expansion, home automation, instrumentation, and embedded designs. Favoured by both industrial engineers and tech students, its small footprint and proven reliability make it a staple for switching low-to-moderate loads.

At Communica, South Africa's trusted distributor of industrial relays and components since 1977, you can source the AXE007M2 from local stock. This means practical lead times, technical backup, and familiar VAT invoicing for business and educational institutions alike.

Typical Uses for AXE007M2 in South Africa

  • Control of small motors, lamps, and solenoid valves
  • Signal switching in automation PLCs and interface boards
  • Isolation relay in university robotics and IoT builders' kits
  • Panel retrofits where PCB relays with reliable operation are required

Key Technical Specifications

Parameter AXE007M2 Spec Notes
Contact Form SPST-NO (1 Form A) Single pole, normally open
Coil Voltage Typically 5V / 12V DC Consult datasheet for variants
Contact Rating 6A @ 250VAC / 30VDC Max resistive load
Mounting PCB Through-hole soldering
Isolation 4,000 Vrms Coil-contact insulation
Note: Always confirm the exact voltage, coil resistance, and contact configuration needed for your application before ordering. Datasheets and technical support are available from Communica on request.

Why Buy AXE007M2 Relays Locally at Communica?

For South African engineers, students, and procurement teams, local stocking of the AXE007M2 means you get:

  • Ready-to-dispatch relay inventory at Communica's Samrand, Pretoria, and Cape Town branches
  • Quotes, VAT invoices, and B2B accounts for project or corporate purchases
  • Knowledgeable local support for relay selection, circuit integration, and accessory matching
  • Access to related sockets, bases, and interface components via Relays Category

Lead times are typically same-day for in-stock branches. For bulk orders or less common variants, Communica can provide reliable sourcing timelines based on international supplier pipelines.

Related Circuit Protection & Passive Components Products

Discover quality circuit protection & passive components products related to AXE007M2 Supplier in South Africa - Reliable Local Stock & Technical Support

Picaxe-14 Project Board - Supports Up To 6 I/o With 3 Analog/touch Sensors

Picaxe-14 Project Board - Supports Up To 6 I/o With 3 Analog/touch Sensors

PicaxeIoT Kits
ZAR120.00

Picaxe-14 Project Board - Supports Up To 6 I/o With 3 Analog/touch Sensors

Smallest Axe007m2 Picaxe-08m2 Ic With 6 I/o And 3 Analog/touch Sensor Channels

Smallest Axe007m2 Picaxe-08m2 Ic With 6 I/o And 3 Analog/touch Sensor Channels

PicaxePICAXE Microcontrollers
ZAR63.25

Smallest Axe007m2 Picaxe-08m2 Ic With 6 I/o And 3 Analog/touch Sensor Channels

How to Select & Specify AXE007M2 Relays

  • Identify coil voltage requirement (5V, 12V, or 24V DC) per your control circuit voltage.
  • Confirm load type and contact rating needed (resistive vs. inductive-always derate for motors or solenoids).
  • Check PCB footprint compatibility or available relay sockets in your design.
  • Match quantity with in-stock availability-see in-stock availability-see Communica site or branch for live info.

Relay Application Example (South Africa Context)

A Tshwane-based university lab is building a process automation demo. Each module needs to switch up to 220V AC lamps (3A each) with isolation from a 12V digital output. The engineer selects the AXE007M2-12V relay, ensuring at least double the expected load rating for safety margin. They use the following circuit wiring for control:

+12V ---[Relay Coil]---[NPN Driver Q1]---GND
Digital Out ---|B  (base drive to Q1)
Contact NO/COM: Switched AC load

Comparison Table - AXE007M2 vs. Common Alternatives

Relay Model Contact Rating Coil Voltage Options Mounting
AXE007M2 6A 250VAC/30VDC 5V, 12V, 24V DC PCB
Omron G5LE 10A 250VAC/30VDC 5V, 12V, 24V DC PCB
Songle SRD-05VDC-SL-C 10A 250VAC/30VDC 5V, 12V DC PCB

Sourcing and Support

Tip: If the exact coil voltage or form factor isn't available, Communica's technical team can advise on alternatives from stocked brands like Omron, Finder, and Songle with comparable pinouts.

Sources

Communica Samrand — Electronic Component Experts

Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.

Last updated: June 12, 2026

Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.

Frequently Asked Questions

Get answers to common questions about Circuit Protection And Passive Components

Why Choose Communica?

*Free Shipping

Free shipping for orders over ZAR 1,000.00.

7-Day Returns

Get a full refund if you had the product for less than 7 days.

Quick Delivery