4-Core 0.34mm2 Sensor Cable for Sale in South Africa | Reliable Supplier Guide
Source 4-core 0.34mm2 sensor cable for industrial, automation, and maker projects. Local supplier with top brands, branch pickup, VAT invoicing & expert support.

Exact Sizing & Applications
Understand where 0.34mm2 4-core cables fit in sensors, PLCs, and control circuits.
Quality Brands, Local Stock
Access leading cable brands and check real-time South African availability at Communica.
Spec Selection for SA Use
Practical tips for insulation, wiring, and VAT invoicing for students and industry.
Overview: What Is a 4-Core 0.34mm2 Sensor Cable?
Sensor cables with 4 conductors (cores) and a cross-sectional area of 0.34mm2 (roughly equivalent to AWG 22) are a staple in industrial automation, field instrumentation, and even hobby environments. These cables offer a blend of flexibility and current-carrying capability, well-suited for connecting proximity sensors, limit switches, encoders, and low-power actuators to PLCs, relays, or measurement equipment.
Communica stocks 4-core 0.34mm2 sensor cables in a range of sheath materials and lengths, ideal for South African plant floors, control panels, or tertiary lab builds. Choosing the right spec can save wiring hassles and downtime in demanding SA conditions.
Typical Applications of 4-Core Sensor Cable
- Wired sensors (inductive, capacitive, photoelectric, ultrasonic) for machinery and robotics
- Signal wiring between automation controllers (PLCs), field devices, and I/O racks
- Neat harnessing of four signal or low-current power lines (e.g., supply + ground + 2 signals)
- Prototyping and bench work for student engineering projects needing multi-conductor wiring
Core Standards & Typical Specs
| Feature | Common Spec | Communica Example |
|---|---|---|
| Number of Conductors | 4 | 4-core |
| Conductor Size | 0.34mm2 (approx. 22 AWG) | 0.34mm2 tinned copper |
| Sheath Material | PVC or PUR | PVC; PUR available |
| Operating Voltage | Up to 250V (signal use) | Check datasheet |
| Temperature Range | -20 degreesC to +80 degreesC (PVC) | -20 degreesC to +80 degreesC (typical) |
Why Choose 0.34mm2 for Sensors?
0.34mm2 offers a balance between flexibility and electrical robustness for most sensor wiring tasks. For runs up to several metres with currents below 2A and signal-level voltages (e.g., 24V DC), this size minimises voltage drop while remaining easy to terminate and route in compact spaces.
Local Brand Availability at Communica
- Brands such as ASK, Lapp Kabel, and Alpha Wire can be sourced locally.
- Core colour codes: Many 4-core cables use black, brown, blue, and white or green/yellow for earth/signal consistency. Confirm before wiring for standards compliance.
- Stock is available for branch collection (Samrand, Pretoria CBD, Cape Town) and via local distributors. Check current stock at Branches & Trading Hours.
Related Connectors, Wire & Cable Products
Discover quality connectors, wire & cable products related to 4-Core 0.34mm2 Sensor Cable for Sale in South Africa | Reliable Supplier Guide
Ehj2 Easyhold Slide-on Cover Box 30w J-box For Security & Electrical Applications
Ehj2 Easyhold Slide-on Cover Box 30w J-box For Security & Electrical Applications
Controllino Maxi Automation Open-source Atmega2560 Plc-arduino Compatible 16mhz
Controllino Maxi Automation Open-source Atmega2560 Plc-arduino Compatible 16mhz
Communica Hdmi-hdmi 10m 4k Premium Cstv2.0 Computer Network Leads
Communica Hdmi-hdmi 10m 4k Premium Cstv2.0 Computer Network Leads
20 Meter, Premium High Speed Hdmi Cable, Hdtv4k 2.0v, 24k Gold-plated Connector, Aluminum Alloy Housing, Can Maintain Accurate Auxiliary And High Dura
20 Meter, Premium High Speed Hdmi Cable, Hdtv4k 2.0v, 24k Gold-plated Connector, Aluminum Alloy Housing, Can Maintain Accurate Auxiliary And High Dura
Rf Transmitter & Receiver 315mhz Remote Control 100mt Line Of Site
Rf Transmitter & Receiver 315mhz Remote Control 100mt Line Of Site
Tm1637 4 Digit Common Anode Red Led Display
Tm1637 4 Digit Common Anode Red Led Display
Communica Hdmi-vga Cable Pst 1,8m Computer Network Leads
Communica Hdmi-vga Cable Pst 1,8m Computer Network Leads
Cab01-4,0mrd Spw | 4mm Solar Panel Wire Multi-strand Flexible Red Tinned Copper Double Insulated 1500vdc Frnc - (price Per Meter)
Cab01-4,0mrd Spw | 4mm Solar Panel Wire Multi-strand Flexible Red Tinned Copper Double Insulated 1500vdc Frnc - (price Per Meter)
Siemens 3ul2303-1a Residual-current Transformer For Residual Current Monitoring Bushing Opening 55mm Residual Current 30ma, 40 A
Siemens 3ul2303-1a Residual-current Transformer For Residual Current Monitoring Bushing Opening 55mm Residual Current 30ma, 40 A
Bobbin Round Bar Black For Electric Fencing
Bobbin Round Bar Black For Electric Fencing
Communica Bmt Ac Current Sensor Clamp-30a Sensors
Communica Bmt Ac Current Sensor Clamp-30a Sensors
Aluminium Wire 1,6mm 1000m Braided/stranded For Electric Fencing
Aluminium Wire 1,6mm 1000m Braided/stranded For Electric Fencing
How to Select 4-Core 0.34mm2 Sensor Cable: Practical Criteria
- Sheath Material: PVC for low-cost and static runs; PUR for dynamic or harsh industrial sites.
- Shielding: Braided shielding reduces EMI, important for analog signals or installations near heavy machinery.
- Length: Cut-to-length purchase is typical in SA; confirm available reel stock at order. Pre-cut 5m/10m lengths are common.
- Operating Temperature: Ensure the cable can handle your application's environment, typical SA ambient is -10 degreesC to +40 degreesC in most enclosures.
- Termination: 4-core cables can be easily ended in screw terminals, IDC/plug connectors or soldered PCBs.
Current & Voltage Drop Calculations (Example)
For a run of 10m to a sensor using 0.34mm2 copper (resistivity ~ 55 mOhm/m), maximum safe current is 2A (derate for bundles or heat). Voltage drop (Vdrop) is:
Vdrop = 2 x length x current x cable resistance per metre
E.g., for 10m at 0.5A: Vdrop = 2 x 10 x 0.5 x 0.055 = 0.55V (within spec for most sensors at 24V).
Example Wiring Diagram (ASCII)
Sensor |-----|==============|-----| PLC Terminal Block
Pins: V+ | 1 |--------------| 1 | V+
0V | 2 |--------------| 2 | 0V
Signal | 3 |--------------| 3 | Input
Shield | 4 |--------------| 4 | GND/Shield
Ordering & Practical SA Notes
- Cut-to-length service and ZAR VAT invoices available for companies, tertiary institutions, and hobbyists.
- Lead times on special insulation types (like PUR or shielded) can range from overnight to 5-7 business days.
- Collection/pickup from Samrand, Pretoria CBD, or Cape Town can be arranged to avoid courier lead times.
Troubleshooting: Common Issues in Sensor Cable Selection
- Incorrect core allocation: Double-check core colours and function (refer to cable datasheet and sensor/PLC manual).
- Mechanical damage: Look for visible nicks, crushing, or insulation wear during installation - especially in moving applications.
- Signal interference: If experiencing noisy readings, consider shielded sensor cable and check that shield is grounded correctly at one end.
- Overlength runs: Calculate voltage drop for runs over 10m; if excessive, choose thicker cable or reduce cable length where possible.
Sources
Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.
Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.
Frequently Asked Questions
Get answers to common questions about Connectors Wire And Cable
Why Choose Communica?
*Free Shipping
Free shipping for orders over ZAR 1,000.00.
7-Day Returns
Get a full refund if you had the product for less than 7 days.