4-Core 0.34mm2 Sensor Cable for Sale in South Africa - Stock, Specs & Local Pricing
Shop 4-core 0.34mm2 sensor cable at Communica. Ideal for sensors/automation. Check local stock, compare specs, branch pickup & get quick pricing.

Trusted Local Stock
Browse in-stock sensor cables with fast lead times and VAT invoicing from Communica.
Spec Clarity & Application
Review conductor size, insulation, shielding, and typical suitability for sensors and automation.
Easy Collection & Quotes
Order online for branch pickup, courier delivery, or request a formal quote for your next project.
Overview: 4-Core 0.34mm2 Sensor Cables for South African Applications
The 4-core 0.34mm2 sensor cable is a staple wiring option for industrial sensors (inductive, capacitive, photoelectric), automation control, light industrial machine builds, and environments where multi-core low-voltage connectivity is required. This cable size balances compact routing with sufficient current-carrying capacity and signal integrity, making it a common choice for connecting limit switches, proximity sensors, and PLC I/O devices. Communica stocks a range of sensor cables-with various sheath and shield types-in convenient cut lengths or reels for OEMs, students, and technicians.
Typical Specifications & Standards
| Feature | Typical Value | SA Relevance |
|---|---|---|
| Core Count | 4 cores (multi-stranded) | Fits most common sensor wiring (3- and 4-wire sensors) |
| Conductor Area | 0.34mm2 (approx. 22 AWG) | Supports data/sensor and low-power signal lines |
| Voltage Rating | Typically 300V | Aligns with most 24VDC PLC/control circuits |
| Insulation Material | PVC, PUR, or TPE | Choose for bending, resistance, or outdoor factors |
| Shielding | Unshielded or tinned copper braiding | EMI-sensitive or noisy environments add shielding |
This core/conductor sizing is widely used for:
- Connecting sensors to PLC and control systems
- Industrial limiting/stop switches and encoders
- Machine vision triggers and safety relays
- DIY automation builds or student training panels
How to Select the Right 4-Core 0.34mm2 Cable
- Check cable outer diameter for your connectors or cable glands-most commonly 4-6 mm OD.
- Choose insulation: PVC for general use, PUR/TPE for repeated movement or oil/chemical exposure.
- Determine if EMC shielding is required (for VSDs, high-power switching, or high-EMI areas).
- Select cable sheath colour: grey/black for panel, yellow/orange for safety/e-stop circuits.
- Decide on length-sold by metre or reel. Allow for panel entry and service loop where needed.
Popular sensor cable brands stocked include LAPP, HELUKABEL, SAB Brckskes, and generic industrial ranges, ensuring compliance with demanding site needs.
Related Connectors, Wire & Cable Products
Discover quality connectors, wire & cable products related to 4-Core 0.34mm2 Sensor Cable for Sale in South Africa - Stock, Specs & Local Pricing
Ehj2 Easyhold Slide-on Cover Box 30w J-box For Security & Electrical Applications
Ehj2 Easyhold Slide-on Cover Box 30w J-box For Security & Electrical Applications
Controllino Maxi Automation Open-source Atmega2560 Plc-arduino Compatible 16mhz
Controllino Maxi Automation Open-source Atmega2560 Plc-arduino Compatible 16mhz
Communica Hdmi-hdmi 10m 4k Premium Cstv2.0 Computer Network Leads
Communica Hdmi-hdmi 10m 4k Premium Cstv2.0 Computer Network Leads
20 Meter, Premium High Speed Hdmi Cable, Hdtv4k 2.0v, 24k Gold-plated Connector, Aluminum Alloy Housing, Can Maintain Accurate Auxiliary And High Dura
20 Meter, Premium High Speed Hdmi Cable, Hdtv4k 2.0v, 24k Gold-plated Connector, Aluminum Alloy Housing, Can Maintain Accurate Auxiliary And High Dura
Rf Transmitter & Receiver 315mhz Remote Control 100mt Line Of Site
Rf Transmitter & Receiver 315mhz Remote Control 100mt Line Of Site
Tm1637 4 Digit Common Anode Red Led Display
Tm1637 4 Digit Common Anode Red Led Display
Communica Hdmi-vga Cable Pst 1,8m Computer Network Leads
Communica Hdmi-vga Cable Pst 1,8m Computer Network Leads
Cab01-4,0mrd Spw | 4mm Solar Panel Wire Multi-strand Flexible Red Tinned Copper Double Insulated 1500vdc Frnc - (price Per Meter)
Cab01-4,0mrd Spw | 4mm Solar Panel Wire Multi-strand Flexible Red Tinned Copper Double Insulated 1500vdc Frnc - (price Per Meter)
Siemens 3ul2303-1a Residual-current Transformer For Residual Current Monitoring Bushing Opening 55mm Residual Current 30ma, 40 A
Siemens 3ul2303-1a Residual-current Transformer For Residual Current Monitoring Bushing Opening 55mm Residual Current 30ma, 40 A
Bobbin Round Bar Black For Electric Fencing
Bobbin Round Bar Black For Electric Fencing
Communica Bmt Ac Current Sensor Clamp-30a Sensors
Communica Bmt Ac Current Sensor Clamp-30a Sensors
Aluminium Wire 1,6mm 1000m Braided/stranded For Electric Fencing
Aluminium Wire 1,6mm 1000m Braided/stranded For Electric Fencing
Practical Specs and Application Examples
To help choose the right cable, consider a typical scenario for South African users:
Example: Wiring a 4-wire inductive proximity sensor (Brown = +24V, Blue = 0V, Black/White = signal outputs) back to a panel-mounted PLC. Estimated cable run: 12 metres with some cable tray sharing with 230VAC power lines.
| Spec Aspect | Selection Criteria |
|---|---|
| Mechanical Flex | Select PUR sheath for frequent bending or drag chain installs |
| EMI Protection | Preferred: tinned copper shield if sharing tray with power wiring |
| Current Capacity | 0.34mm2 supports up to ~3-5A at low voltage over short runs* |
| Labelling | Choose colored inner wires for easy identification (VDE standard: BN, BU, BK, WH) |
V_{drop} = I_{load} \times R_{cable} where R_{cable} for 0.34mm2 ~ 58 Ohm/km.Comparing Options & Local Buying Notes
- Standard PVC insulation is rugged for most factory or tertiary training labs.
- PUR sheaths offer oil/chemical resistance for food or automotive environments.
- Shielded cable is recommended if runs cross inverters or large relays.
- Branch stock can vary-Samrand warehouse typically has the widest range.
- Get VAT-inclusive invoices for schools, businesses, or project claims.
Troubleshooting Cable Related Issues
- Intermittent sensor readings? Check for EMI-try shielded cable and correct earthing.
- Brittle cables or exposed wires? Inspect for incorrect sheath selection for the application.
- Excess voltage drop on long runs? Consider upsizing to 0.5mm2 or parallel runs.
- Connector fit issues? Match OD to gland spec and cross-check datasheets via Connectors category.
Conclusion: Why Source Your 4-Core 0.34mm2 Cable from Communica?
With thousands of metres in regular local stock, technical support, and the ability to supply VAT invoices and cut-to-length quantities, Communica provides a streamlined buying experience for South African engineers, technicians, and students. Compare specifications, check in-branch stock online, and ensure your automation or sensing project stays on schedule.
Sources
Communica supplies semiconductors and electronic components to industries such as automotive, electrical, automation, mining, and education.
Disclaimer: This content is for educational purposes only. Product availability, pricing, and specifications are subject to change. Always verify current details on the retailer's website before making a purchase. We may earn affiliate commissions from qualifying purchases.
Frequently Asked Questions
Get answers to common questions about Connectors Wire And Cable
Why Choose Communica?
*Free Shipping
Free shipping for orders over ZAR 1,000.00.
7-Day Returns
Get a full refund if you had the product for less than 7 days.
Quick Delivery
Nationwide delivery within 2 - 4 working days.
























